What was found
CABIN FLOORBEAM STA 986 LEFT SIDE UPPER SURFACE O/B HAS CORROSION AT DOME NUT. GROUNDED - YES. REMOVED CORROSION IAW SRM 51-10-02, ORIG MAT .150" IAW SRM 53-70-51 TABLE 6, FIG 6, LOSS .055" OF MAT, REMAINING MAT .095" FOUND TO BE BEYOND LIMITS IAW SRM 53-70-51-1A. REPAIRED TCAP 986 FLOORBEAM UPPER SURFACE, LEFT SIDE IAW SRM 53-00-51, REPAIR 1.