What was found
NR 2 ENGINE SHOWS SHORT TIME FAULT MESSAGE 75-20372, THE HMU VSV CONTROL CURRENT IS OUT OF RANGE. ACFT GROUNDED. TROUBLESHOT IAW FIM 75-31, TASK 801, PERFORMED EEC ACTUATORS TEST IAW AMM 71-00-00-707-807-F00, TEST PASSED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NR 2 ENGINE SHOWS SHORT TIME FAULT MESSAGE 75-20372, THE HMU VSV CONTROL CURRENT IS OUT OF RANGE. ACFT GROUNDED. TROUBLESHOT IAW FIM 75-31, TASK 801, PERFORMED EEC ACTUATORS TEST IAW AMM 71-00-00-707-807-F00, TEST PASSED.