Service difficulty report · Connector · Boeing 737890

Difficulty date
September 19, 2017
Submitted
September 21, 2017
Operation
Air carrier
Aircraft
N586AS
Make and model
Boeing 737890
Aircraft serial
35189
Aircraft time
37,881 hours, 11,547 cycles
Part
Connector
Condition
Obstructed
Location
Temp Sensor Fan
Stage of operation
NR
How discovered
9
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

WHEN THE CONTROL CABIN TEMP CONTROLLER IS RUN IN AUTO, IT DRIVES TO 60 DEG C. HAD TO RUN IN OFF POSITION. ACFT GROUNDED. VERIFIED DEFECT. FOUND CONTROL CABIN TEMP SENSOR FAN INOPERATIVE. FOUND THE CONNECTOR D40687J LABLE PREVENTING FAN FROM OPERATING. SECURED LABEL, TEMP SENSOR FAN NOW OPS NORMAL. IAW AMM 21-61-11 CONTROL CABIN TEMP OPS CHECKED NORMAL.