Service difficulty report · Filter · Boeing 737990ER

Difficulty date
September 20, 2017
Submitted
September 25, 2017
Operation
Air carrier
Aircraft
N472AS
Make and model
Boeing 737990ER
Aircraft serial
60580
Aircraft time
9,777 hours, 3,200 cycles
Part
Filter
Condition
Dirty
Location
Temp Sensor
Stage of operation
NR
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CONTROL CABIN ZONE TEMP LIGHT, RECALL RESETS WITH MASTER CAUTION RESET. ACFT GROUNDED. FOUND THE FLT DECK TRIM VALVE FAULT NR 2 PACK-ZONE TEMP CONTROLLER. RESET FAULT. FOUND CONTROL CABIN TEMP SENSOR ASSY FILTER DIRTY. RESET FAULT AND CLEANED THE TEMP SENSOR FILTER, PERFORMED MULTIPLE PACK-ZONE TEMP BITES, NO DEFECTS NOTED. RAN RT PACK HOT & COLD MULTIPLE TIMES, NO DEFECTS NOTED. NO HISTORY 60 DAYS IAW AMM 21-61-06.