What was found
R2 DOOR LOWER SILL, FLOOR CUSP WEB BS 950 - 990 HAS SURFACE CORROSION. ACFT GROUNDED. REMOVED CORROSION IAW SRM 51-10-02. FOUND BEYOND LIMITS IAW SRM 53-70-15. FABRICATED A NEW CUSP WEB IAW DWG 147A8510 REV A . REMOVED AND REPLACED THE CUSP WEB IAW SRM 51-40-02, DWG 147A8501 REV-, EA 900-53-19364, REV P1, SOPM 20-43-03, AND SOPM 20-41-02.