Service difficulty report · Control Valve · Boeing 737990ER

Difficulty date
October 12, 2017
Submitted
October 16, 2017
Operation
Air carrier
Aircraft
N469AS
Make and model
Boeing 737990ER
Aircraft serial
41702
Aircraft time
12,869 hours, 4,258 cycles
Part
Control Valve
Part number
3989085
Part serial
20282
Condition
Faulted
Location
Lt Acm
Part time
13,716 hours, 4,798 cycles
Stage of operation
NR
How discovered
V
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

LEFT PACK LIGHT ILLUMINATED AFTER RECALL, LIGHT GOES OUT WHEN PUSHING MASTER CAUTION. ACFT GROUNDED. PERFORMED A PACK/ZONE TEMP CONTROLLER BITE IAW FIM 21-62, TASK 801, THE LEFT PACK TEMPERATURE CONTROL VALVE FAULT CONFIRMED BY VERIFY TEST. REMOVED, REPLACED, AND TESTED THE LEFT PACK TEMPERATURE CONTROL VALVE IAW AMM 21-51-10-000-801, AND AMM 21-51-10-400-801. OPS NORMAL, NO LEAKS NOTED. PERFORMED PACK/ZONE TEMP CONTROLLER BITE IAW FIM 21-62, TASK 801, NO FAULTS FOUND.