What was found
PASSENGER COMPARTMENT FLOORBEAM CORRODED STA 947.5 RBL 50. GROUNDED - YES. REMOVED CORROSION, ORIGINAL MATL. THICKNESS .180", REMOVED .120", .060" REMAINING, FOUND TO BE OUT OF LIMITS. REMOVED UPPER T-CHORD FROM FLOORBEAM AND INSTALLED 2 EA. REPAIR SECTION T-CHORDS AND SPLICE ANGLES REF SRM 57-70-51-1A-1, 53-70-51-2R-5, AND DWG 147A5650.