What was found
CABIN FLOOR STRAP BS 1019, LBL 18 CORRODED. ACFT GROUNDED. LOCATED & DRILLED A NEW STRAP IAW DWG 147A5700. REMOVED AND INSTALLED THE NEW STRAP IAW SRM 51-40-02 AND DWG 147A5700.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.