What was found
CABIN FLOOR STRAP BS 1019, RBL 3 CORRODED. ACFT GROUNDED. REMOVED, LOCATED, DRILLED, INSTALLED A NEW STRAP IAW DWG 147A5700, AND SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CABIN FLOOR STRAP BS 1019, RBL 3 CORRODED. ACFT GROUNDED. REMOVED, LOCATED, DRILLED, INSTALLED A NEW STRAP IAW DWG 147A5700, AND SRM 51-40-02.