What was found
AFT CARGO COMPARTMENT DOOR SURROUND, FWD SHIELD STA 767-794 IS CORRODED. GROUNDED - YES. REMOVED CORROSION FOUND BEYOND ALLOWABLE LIMITS IAW SRM 53-60-15-1A-1, ORIGINAL MAT THICKNESS IS .050. REMAINING IS .043, REMOVED .007. REMOVED AND INSTALLED NEW SHIELD IAW DWG 146A0081, REV= - AND SRM 51-40-02.