What was found
CABIN BS 1026 FLOOR WEB CORRODED LBL 2. ACFT GROUNDED. REMOVED THE WEB IAW SRM 51-40-02. LOCATED, DRILLED, AND INSTALLED A NEW WEB IAW DWG 147A5700 AND SRM 51-40-05.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CABIN BS 1026 FLOOR WEB CORRODED LBL 2. ACFT GROUNDED. REMOVED THE WEB IAW SRM 51-40-02. LOCATED, DRILLED, AND INSTALLED A NEW WEB IAW DWG 147A5700 AND SRM 51-40-05.