As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
PASSENGER COMPARTMENT FLOOR STA 1006 FLOORBEAM CORRODED RBL 32. GROUNDED - YES. REMOVED CORROSION AND CHECKED LIMITS. ORIGINAL THICKNESS .125 MATERIAL LOSS .029 MATERIAL REMAINING IS .096 FOUND TO BE OUT OF LIMITS IAW SRM 53-70-51-1A-1. REPAIRED DAMAGED AREA IAW EA 900-53EA-19447 REV 00.