What was found
CENTER FLOOR SUPPORT FROM BS 259 - 270, BL 0 IS CORRODED. ACFT GROUNDED. LOCATED AND DRILLED A NEW FLOOR SUPPORT IAW SRM 51-40-05-0G. INSTALLED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CENTER FLOOR SUPPORT FROM BS 259 - 270, BL 0 IS CORRODED. ACFT GROUNDED. LOCATED AND DRILLED A NEW FLOOR SUPPORT IAW SRM 51-40-05-0G. INSTALLED.