Service difficulty report · Connector · Boeing 737890

Difficulty date
October 31, 2017
Submitted
December 12, 2017
Operation
Air carrier
Aircraft
N577AS
Make and model
Boeing 737890
Aircraft serial
35186
Aircraft time
40,334 hours, 12,013 cycles
Engine
Cfmint CFM567B27
Part
Connector
Condition
Corroded
Location
T3 Sensor
Stage of operation
IN
How discovered
9
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

PERFORMED T/C 78273000, NR 2 ENGINE HAS LONG TIME FAULT 75-10832, THE T3 SIGNAL IS OUT OF RANGE. ACFT GROUNDED. VERIFIED DEFECT, FAULT LOGGED IN RECENT AND FAULT HISTORY LEGS 0 THRU 10. FOUND THE T3 SENSOR VALUES HIGHER THAN NR 1 ENGINE. WHILE REMOVING T3 SENSOR CONNECTORS FOUND EVIDENCE OF CORROSION IAW WDM 75-31-21. CLEANED THE CONNECTORS DP1005 AND DP0905 AT T3 SENSOR AND DP0909 AND DP1010 AT THE EEC. RAN THE NR 2 ENGINE, NO FAULTS LOGGED IN FLIGHT LEG 0. EEC TEST PASSED IAW AMM 73-21-00.