What was found
STA 947 FRAME LOWER SPLICE PLATE AT BETWEEN STR 23R - 24R AFT SIDE HAS CORROSION. GROUNDED - YES. REMOVED, FABBED NEW AND INSTALLED FRAME SPLICE IAW DWG 147A1100 REV A. ALODINED AND PRIMED IAW DWG 147A1100 REV A.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STA 947 FRAME LOWER SPLICE PLATE AT BETWEEN STR 23R - 24R AFT SIDE HAS CORROSION. GROUNDED - YES. REMOVED, FABBED NEW AND INSTALLED FRAME SPLICE IAW DWG 147A1100 REV A. ALODINED AND PRIMED IAW DWG 147A1100 REV A.