What was found
FOUND A DENT BELOW THE R1 DOOR BS 295, STRINGER 22R. ACFT GROUNDED. REPAIRED DAMAGE TO SKIN IAW B737 800 SRM 53 00 01 2R 1 THIS IS A CATEGORY B REPAIR WITH AN INSPECTION THRESHOLD OF 50,000 FLT. CYCLES, INTERVAL OF 3,440 FLT. CYCLES. REFER TO 737 800 APB SRM SUPPLEMENT 53 00 01 FOR INSPECTION REQUIREMENTS AND INTERVALS. ENTRY MADE IN FILEMAKER SUPPLEMENTAL DEFECT DATABASE FOR CAT B REQUIREMENTS 74711 RTOWELL.