Service difficulty report · Bleed Valve · Boeing 737890

Difficulty date
December 8, 2017
Submitted
December 11, 2017
Operation
Air carrier
Aircraft
N569AS
Make and model
Boeing 737890
Aircraft serial
35184
Aircraft time
40,915 hours, 12,559 cycles
Engine
Cfmint CFM567B27
Part
Bleed Valve
Part number
32145526
Part serial
11179
Condition
Failed
Location
Nr 1 Engine
Part time
23,943 hours, 9,413 cycles
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

PERFORMED BLEED OFF TAKEOFF IN HNL. UPON CONFIGURING BLEEDS; #1 BLEED VALVE DID NOT OPEN. OPENED ISO VALVE TO CONFIRM #1 PACK OPERATION. L DUCT PRESS SHOWED ZERO W/PACK & BLEED SW ON W/ISO VALVE IN AUTO. ATTEMPTED NUMEROUS RECYCLES OF SWITCHES. CONTACTED MX CTRL AND AS WE WERE CLIMBING THRU 12000' & WAITING FOR MX; VALVE OPENED & OPS NORMAL FOR REMAINDER OF FLIGHT. MX ADVISED TO CONTINUE 7 WRITE UP EVENT IN PDX GROUNDED - YES. PERFORMED HEALTH CHECK OF THE #1 ENGINE PRSOV AND FOUND PRSOV WITH POOR RESPONSE USING WRENCH ON MANUAL OVERRIDE. REMOVED & REPLACED THE #1 ENGINE PRSOV REF B737-800 AMM 36-11-04. OPS CK LEAK CK GOOD, NO OTHER DEFECTS NOTED. NO OTHER HISTORY WITHIN 30 DAYS.