As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ABORTED NR 1 ENGINE START DUE TO NO LIGHT OFF. RETURNED TO GATE. ACFT GROUNDED. RESTORED THE ACFT TO ORIGINAL CONFIGURATION. PERFORMED FIM 74-21, TASK 807. AUDIBLE TEST AND NR 1 ENGINE START GOOD. NO HISTORY 60 DAYS. AS A PRECAUTION, REMOVED AND REPLACED RT MAIN IGNITER PLUG IAW AMM 74-21-02, OPS CHECKED GOOD.