What was found
NR 2 ENGINE, T49.5 EGT PROBES BEFORE AND AFTER CLEANING READOUT, EGT PROBE S3 SHOWS DASHES. ACFT GROUNDED. PERFORMED FIM 77-31 TASK 803. CLEANED THE CONNECTORS IAW AMM 77-21-00. PERFORMED RESISTANCE CHECK OF J10 TO DP1010, RESISTANCE CHECKED GOOD. PERFORMED RESISTANCE CHECK OF S3 EGT PROBE, RESISTANCE CHECKED GOOD IAW AMM 77-21-00. PERFORMED EEC TEST EEC, TEST PASSED IAW AMM 73-21-00.