What was found
FWD CARGO PIT BETWEEN STA 500G TO 500H, RT TRANSITION HAS AREAS OF CORR OVER PREVIOUS BLENDOUT. GROUNDED - YES. REMOVED AND REPLACED TRANSITION PANEL IAW SRM 51 40 02 0G 0 W 1 O .040 R .032 L 1.75 D .008.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD CARGO PIT BETWEEN STA 500G TO 500H, RT TRANSITION HAS AREAS OF CORR OVER PREVIOUS BLENDOUT. GROUNDED - YES. REMOVED AND REPLACED TRANSITION PANEL IAW SRM 51 40 02 0G 0 W 1 O .040 R .032 L 1.75 D .008.