What was found
THE T25 SIGNAL IS OUT OF RANGE, LONG TIME FAULT FOUND DURING EEC BITE TEST. ACFT GROUNDED. PERFORMED FIM 75-33 TASK 801. NO FAULTS. NR 2 ENG BITE TEST, RECENT FAULTS HAS CODE 75-10802 (CH A), 75-20802 (CH B), AND 75-10822. EEC, J9 AND J10 HARNESS PREVIOUSLY REPLACED. POSSIBLE CAUSE IAW FIM 75-33 TASK 801 IS THE PT25 SENSOR. R & R THE PT25 SENSOR FOR THE NR 2 ENGINE IAW AMM 73-21-02. OPS TESTED GOOD.