What was found
LEFT PACK LIGHT ILLUMINATED ON RECALL. PERFORMED A BITE CHECK ON BOTH PACK, ZONE TEMP CONTROLLERS IAW AMM 21-61-00-700-806-002, NR 1 CONTROLLER SHOWS EXIT LATCHED, RESET FAULTS, BITE CHECKED. NO FAULT NOTED. PERFORMED FIM 21-62 TASK 853, CHECKED GOOD TO E (3) VERIFIED GREEN. NO FURTHER ACTION REQUIRED. NO HISTORY 30 DAYS. ACFT GROUNDED.