What was found
AFT CARGO BAY WEB AT THE DOOR CUTOUT CORRODED AT MULTIPLE PLACES. ACFT GROUNDED. REMOVED DAMAGE IAW SRM 51-10-02. FOUND OUT OF LIMITS IAW SRM 50-60-15, DETAIL 6. REMOVED AND REPLACED THE WEB IAW SRM 51-40-02, SRM 51-40-05, AND DWG 146A8340, REV A.