What was found
SIGNAL DISAGREE, SHORT TIME FAULT, FOUND DURING EEC BITE TEST. ACFT GROUNDED. VERIFIED FAULT IN RECENT FAULTS & FAULT HISTORY. FAULT IS INTERMITTENT. ALSO FOUND ASSOCIATED FAULT CODE 75-20822 ACTIVE AND INTERMITTENT. CHECKED EXTENSIVE HISTORY IN CHAPTERS 73 AND 75, FOUND J9 AND J10 HARNESSES CHANGED, EEC & PT25 SENSORS CHANGED. THE SENSOR READS GOOD IN INPUT MONITORING AND EEC PASSED TEST. REMOVED AND REPLACED THE NR 2 ENG PT25 SENSOR IAW AMM 73-21-02-000-801-F00 & 73-21-02-400-801-F00. OPS CHECKED OK.