What was found
NR 2 ENG RT VSV LEAKING 30 DPM FROM DRAIN. GROUNDED - YES. REMOVED AND REPLACED NR 2 ENG RT VSV ACTUATOR REF AMM 75-31-01 PASSED LEAK CHECK AND OPS CHECKS. CLEARED PLT.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NR 2 ENG RT VSV LEAKING 30 DPM FROM DRAIN. GROUNDED - YES. REMOVED AND REPLACED NR 2 ENG RT VSV ACTUATOR REF AMM 75-31-01 PASSED LEAK CHECK AND OPS CHECKS. CLEARED PLT.