What was found
WHILE ACCOMPLISHING T/C 78273000, FOUND FAULT ON NR 1 ENGINE. SHORT TIME FAULT, MSG NUMBER: 73-11271, THE ALTERNATOR VOLTAGE INPUT TO THE EEC IS OUT OF RANGE. GROUNDED - YES. ACCOMPLISHED T/C 78273000, VERIFIED NR 1 ENG HAVE NO FAULTS MSG FOR THE LAST 5 FLT LEGS. PERFORMED FIM 73-27 TASK 804, NO DEFECTS FOUND, VERIFIED TGB/AGB CHIP DETECTOR IS CLEAN. NR 1 ENG EEC BITE CHECKED GOOD W/O FAULTS AND ENG IDLE RUNS AND LEAKS CHECKED GOOD. CLEARED THIS PLT DEFERRAL.