What was found
DURING POST LEAK CHECK FOR A FUEL NOZZLE REPLACEMENT ON THE NR 1 ENGINE, FOUND RT VSV ACTUATOR LEAKING 15 DROPS PER MINUTE AT THE 6 O'CLOCK POSITION. ACFT GROUNDED. REPLACED THE VSV ACTUATOR IAW AMM 75-31-01-000-802-F00, AND AMM 75-31-01-400-802-F00. ACCOMPLISHED VSV ACTUATOR LEAK TEST IAW AMM 75-31-01-790-801-F00. LEAK CHECKED GOOD. ACCOMPLISHED TESTS FROM POWERPLANT TEST IAW TABLE TEST 12 AND TEST 3A. TEST 12 ACTUATOR TEST, OPS CHECKED GOOD, NO FAULTS. TEST 3A LEAK CHECKED GOOD.