What was found
CORROSION WAS FOUND ON THE FWD CARGO DOOR SURROUND SILL UPPER SURFACE, BS 470. ACFT GROUNDED. REMOVED CORROSION AND FOUND BEYOND ALLOWABLE LIMITS IAW SRM 53-30-15-1A-1. REMOVED THE WEB IAW SRM 51-40-02. FABRICATED A NEW WEB AND INSTALLED IAW DWGS 143A8122, SH 10, REV-, 143A8330, SH 40, REV A, SH 42, REV A, AND SRM 51-40-02.