What was found
PILOT SLIDING WINDOW DIFFICULT TO CLOSE. GROUNDED - YES. FOUND L2 WINDOW HITTING AT AFT UPPER ROLLER. INSTALLED ADDITIONAL SHIM WASHERS IAW AMM 56-12-11-820-801 2 H(5) AND FOUND LOWER AFT LOOSE. RESECURED BOLT IAW AMM 56-12-11-820-801 2. H(4)1)D) AND 2 H (9)(C). PERFORMED OPS TEST OF L2 WINDOW IAW AMM 56-12-11-720-801 OPS TEST GOOD. PERFORMED WINDOW HEAT TEST IAW AMM 30-41-00-710-801. OPS TEST GOOD.