What was found
DURING ACCOMPLISHMENT OF T/C 78273000 FOUND LONG TERM FAULT MSG 76-11362 THE START LEVERS SIGNAL DISAGREE ON NR 2 ENGINE. GROUNDED - YES. NR 2 ENG EEC BITE NO LONGER SHOWS FAULTS 76-11362, -21362, OR -31362 IN RECENT FAULTS. DUE TO HISTORY, REPLACED NR 2 ENG START LEVER REF AMM 76-11-02. GROUND VERIFICATION SUCCESSFUL REF AMM 33-18-00, 28-22-00, 26-10-00, & 71-00-00. CLEARS PLT DEFERRAL.