What was found
DURING ACCOMPLISHMENT OF NR 1 MAIN TANK FQIS TEST REF NG-28FCD-18088-1, FOUND PROBES F3, F5, AND F6 OUT OF TOLERANCE REF AMM TASK 28-41-21-710-801. GROUNDED - YES. REMOVED AND REPLACED PROBES F3, F5, AND F6 OF THE NR 1 MAIN TANK. FQIS SYSTEM TEST PASS. ETOPS GROUND VERIFICATION SUCCESSFUL. QUANTITY INDICATION OPERATIONAL ON BOTH FLIGHT DECK AND REFUEL PANEL DISPLAYS.