What was found
FOUND NR 2 ENGINE ECONOMIC FAULT 77-20862 "THE BOTTOM LEFT EGT SIGNAL IS OUT OF RANGE". GROUNDED - YES. ACCOMPLISHED EGT CLEANING PROCEDURES, BEFORE CLEAN TEMP READS: S1- 126.50, S2- 70.25, S3, S4- 123.12. AFTER CLEAN, TEMPERATURES READS: S1- 65.37, S2- 35.00, S3- 34.62, S4- 63.00, REF AMM 77-21-00-140-801. EEC BITE TEST OPS NML REF AMM 73-21-00-700-804-F00.