What was found
RT ALPHA VANE CAUTION LIGHT ILLUMINATED, C/B P18-3 D3 OPENED HEATER ALPHA VANE RIGHT. GROUNDED - YES. INSPECTED OPEN C/B D3 HEATER ALPHA VANE RIGHT, NO DEFECTS NOTED, RESET BREAKER PER AMM 30-60-01-860-801. PERFORMED OPS TEST OF AUTO AIR DATA SENSOR HEATING, AMM 30-31-00-750-801, STALL WARNING INSTALL TEST AMM 27-32-21 ALL OPS CHECK NORMAL, NO DEFECTS NOTED.