What was found
STA 986 FLOORBEAM UPPER FLANGE CORRODED BETWEEN LBL32 AND RBL 32. GROUNDED - YES. REPAIRED 986 BEAM UPPER CHORD IAW SRM 53 70 51 2R 4 W 1" O .150" R .130" L 1" D .020".
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STA 986 FLOORBEAM UPPER FLANGE CORRODED BETWEEN LBL32 AND RBL 32. GROUNDED - YES. REPAIRED 986 BEAM UPPER CHORD IAW SRM 53 70 51 2R 4 W 1" O .150" R .130" L 1" D .020".