Service difficulty report · Connector · Boeing 737890

Difficulty date
October 20, 2018
Submitted
October 24, 2018
Operation
Air carrier
Aircraft
N581AS
Make and model
Boeing 737890
Aircraft serial
35188
Aircraft time
43,825 hours, 13,159 cycles
Part
Connector
Condition
Dirty
Location
Nr 1 Engine
Stage of operation
IN
How discovered
O
Nature of condition
J
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

NR 1 ENGINE FMC/CDU SHOWS FAULT 75-10831, T3 SIGNAL IS OUT OF RANGE-LONG TIME FAULT. GROUNDED - YES. PER B737-800 FIM 75-33 TASK 802 INITIAL EVALUATION SHOWS FAULT 75-10831 T3 SIGNAL IS OUT OF RANGE. LONG TIME FAULT PRE CLEANING READINGS, T3 CH B: 109.62. T3 CH A: 479.75. CLEANED CH A + B ELECTRICAL CONNECTORS AT T3 PER B737-800 AMM 70-70-01.POST CLEANING READINGS, T3 CH B: 50.37. T3 CH A: 50.75. EEC TEST PASSED NO FAULTS. REPAIR CONFIRMATION SUCCESSFUL.