What was found
MAIN CABIN AFT WET AREA, FLOORBEAM UPPER SURFACE SEVERAL SPOTS CORROSION BS 947.5, LBL 15 - RBL 12. GROUNDED - YES. REMOVED DAMAGE ON 947.5 FLOORBEAM ORIG THICKNESS 0.180, MAT'L REMAINING 0.134, REMOVED 0.046 AND FOUND TO BE OUT OF LIMITS PER SRM 53-70-51-1A-1 AND 53-70-51-01-1, REPAIRED 947.5 FLOORBEAM PER SRM 53-70-51-2R-5. CUT FLOORBEAM AND REMOVED DAMAGED SECTION SPLICED IN NEW SECTION OF FLOORBEAM.