Service difficulty report · Control Valve · Boeing 737890

Difficulty date
November 2, 2018
Submitted
November 6, 2018
Operation
Air carrier
Aircraft
N534AS
Make and model
Boeing 737890
Aircraft serial
35202
Aircraft time
30,835 hours, 8,983 cycles
Part
Control Valve
Part number
3989083
Part serial
233C
Condition
Failed
Location
Lt A/C Pack
Part time
18,895 hours, 5,454 cycles
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CONT CAB ZONE TEMP ILLUMINATED AFTER TAKEOFF. FOLLOWED QRH PROCEDURE - ZONE TEMP ILLUMINATES ONLY ON RECALL INDICATING FAILURE OF FLIGHT DECK PRIMARY OR STANDBY TEMP CONTROL AS PER QRH. GROUNDED - YES. PERFORMED PACK ZONE TEMPERATURE CONTROLLER BITE PER B737-800 AMM 21-61-00-700-806-002 #2 CONTROLLER FAULTED FLT DECK TRIM VALVE. REMOVED AND REPLACED FLT DECK ZONE TRIM VALVE PER AMM 21-61-21. INSTALLATION CHECK GOOD.