What was found
FLOORBEAM AT STA 986 HAS CORR ON SCREW HOLE AT RBL 64. GROUNDED - YES. REPAIRED FLOORBEAM AT STA 986, RBL 24, IAW SRM 53 70 57 2R 6, STEP 4 W 1 O .150 R .120 L 1" D .030.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOORBEAM AT STA 986 HAS CORR ON SCREW HOLE AT RBL 64. GROUNDED - YES. REPAIRED FLOORBEAM AT STA 986, RBL 24, IAW SRM 53 70 57 2R 6, STEP 4 W 1 O .150 R .120 L 1" D .030.