Service difficulty report · Control Valve · Boeing 737990ER

Difficulty date
November 17, 2018
Submitted
November 19, 2018
Operation
Air carrier
Aircraft
N431AS
Make and model
Boeing 737990ER
Aircraft serial
43255
Aircraft time
20,242 hours, 6,679 cycles
Part
Control Valve
Part number
3989085
Part serial
10728
Condition
Inoperative
Location
Rt A/C Pack
Part time
37,071 hours, 11,448 cycles
Stage of operation
TX
How discovered
O
Nature of condition
J
Precautionary procedure
D

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AFTER PUSHBACK AND STARTING ENGINES UPON PRESSING SYSTEM ANNUNCIATOR PANEL FOR RECALL, THE AFT ZONE TEMP LIGHT ILLUMINATED, UPON RESET LIGHT EXTINGUISHED. WE WERE UNABLE TO CONTROL THE AFT CABIN TEMP CONTROL, WITH AFT SELECTOR IN THE AFT DUCT SUPPLY POSITION. THE AFT PASSENGER CABIN TEMP CONTROL TEMPERATURE WAS 34C. GROUNDED - YES. ACCOMPLISHED AFT CABIN TRIM VALVE FAULT ISOLATION FOUND ZONE TRIM MODULATION VALVE BAD. REMOVED AND REPLACED ZONE TRIM MODULATING VALVE REF B737-900 AMM 21-61-21-000-801 AND 400-801. OPS AND LEAK CHECK GOOD PACK ZONE TEMP CONTROLLER BITE CHECK GOOD.