What was found
WHILE PERFORMING AUX BATTERY CHECK PER AMM 24-3H1DC AMP WAS +449 AND BATTERY VOLTAGE WAS 32V NO FAULTS INDICATED DURING ELEC PANEL TEST. GROUNDED - YES. WHILE T/S AUX BATTERY SYSTEM FOUND W2532-2202R-24 BROKEN FROM D10328 REF WDM 24-31-12 PG1. REMOVED WIRE W2532-0531-1/0 AND CUT W2532-2202B-24 6" FROM CD 3256-DC INSTALLED WIRE W2532-0531 & REATTACHED W2532-2202B-24 REF SWPM. SYS OPS NORMAL.