As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
RAMP REPORTS NR 2 ENGINE LEAKING FUEL. GROUNDED - YES. REMOVED AND REPLACED NR 2 ENGINE LEFT VSV ACTUATOR REF AMM 75-31-01. ACTUATOR LEAK TEST, PASS. NO DEFECT NOTED. ACCOMPLISHED TEST 3A & 12. NO FAULT OR LEAKS NOTED. ALT DEACTIVATION PROCEDURE USED PER CHAPTER 5, TABLE 3, ITEM 8. CLEAR PLT. ALT DEACTIVATION PROCEDURE REVERSED.