What was found
FLOOR BEAM STA. 986.5 HAS CORR AROUND DOME NUT HOLE AT LBL45. GROUNDED - YES. REPAIRED FLOOR BEAM UPPER FLANGE IAW 737 800 SRM 53 70 51 2R 4 W 1" O .150" R .065" L 1" D .085".
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR BEAM STA. 986.5 HAS CORR AROUND DOME NUT HOLE AT LBL45. GROUNDED - YES. REPAIRED FLOOR BEAM UPPER FLANGE IAW 737 800 SRM 53 70 51 2R 4 W 1" O .150" R .065" L 1" D .085".