What was found
AFT MAIN CABIN, FLOOR WEB/SUPPORT AT FR68, APPROX 8" I/B OF L2 DOOR AFT CUTOUT, HAS EVIDENCE OF CORROSION AT PREVIOUS REPAIR FILLERS AND DOUBLER, ON UPPER AND LOWER SURFACES, AND CORRODED NUT PLATES. GROUNDED - YES. REMOVED AND REPLACED EXISTING REPAIR PARTS IAW SRM 53-41-14.