What was found
APU TREND DATA SHOWS CT5ATP TEMPERATURE IS AT OR ABOVE THE 605 DEGREE THRESHOLD. GROUNDED - YES. ACCOMPLISHED B737-800 FIM 49-40 TASK 825 STEPS D1 THROUGH D6E. REMOVED AND REPLACED ALL FUEL NOZZLES REF B737-800 AMM 49-31-14. FOUND TOTAL PRESSURE SENSOR ORIFICE PARTIALLY BLOCKED. REMOVED AND REPLACED TOTAL PRESSURE SENSOR REF AMM 49-52-32. OPS CHECK GOOD. NO FUEL LEAKS NOTED. NO FAULTS MESSAGES OR MAINTENANCE MESSAGES ON APU BITE.