What was found
AFT PIT LT TRANSITION PANEL HAS AREAS OF CORR FROM STA 727+8 TO STA 830. GROUNDED - YES. REMOVED CORR FROM AFT PIT LT TRANSITION PANEL FROM STA 727+8 TO STA 830, FOUND TO BE IN LIMITS BETWEEN STA 727+8 AND 727G+8 AND 727I+D AND 830 IAW SRM 53 00 53 1A 2 FIG 103 DETAIL D RESTORED FINISH IAW AMM 51 21 47 370 802 AND AMM 51 21 71 370 802, REMOVED CORR FROM AFT PIT LT TRANSITION PANEL STA 727G+8 TO 727I+12, FOUND TO BE OUT OF LIMITS IAW SRM 53 00 53 1A 2 FIG 103 DETAILD REPAIRED LT TRANSWITION PANEL STA 727G+8 TO 727I+12 IAW SRM 53 00 53 2R 5 RPAIR 5 W 1 O .040 R .018 L 6 D .022.