What was found
FWD AND AFT TEMP CONTROL OUTPUT VERY WARM INDICATED 22DEG REDUCE TEMP TO 8DEG FELT NORMAL TEMP DOES NOT CORRESPOND WITH INDICATION. GROUNDED - YES. ACCOMPLISHED BITE ON BOTH TEMP CONTROLLERS, NO FAULTS FOUND. FOUND BOTH FWD & AFT CABIN TEMP SENSOR FILTERS DIRTY & CLOGGED. CLEANED BOTH FILTERS REF AMM 21-61-06-100-801 OPERATED PACKS & ZONE TEMPS MATCH INDICATION IN FLIGHT DECK.