What was found
AFT MAIN CABIN LEFT SIDE FLOORBOARD SHEAR WEB/PLATE CORRODED BETWEEN FR69 AND FR70 LBL46. GROUNDED - YES. PART BEYOND DWG TOLERANCES REF DWG 18053471124 ORIG .071,100% MAT LOSS, DISCONNECTED 7102VC FOR FOM, REMOVED AFT MAIN CABIN WET AREA FLOORBOARD WEB SUPPORT PER SRM 51-42-11, LOCATED AND DRILLED P# 05347112420200 PER SRM 51-44-11, INSTALLED NEW WEB PER SRM 51-42-11, RECONNECTED 7102VC PER ESPM 20-44-17, PASSED OPS TEST PER CMM 34-55-00-710-001-A REMOVED DOT PO 917042.1.