What was found
CRACK FOUND INBOARD OF RT STABILIZER STA 129.50 MEASURING 1.25" IN LENGTH LOCATED IN THE MIDDLE OF THE BAY. GROUNDED - YES. REMOVED DAMAGE (CUT-OUT) CRACK ON RT STAB STA 129-50, APPROX 16" FWD OF REAR SPAR, ALSO INCLUDED EXISTING REPAIR AT STAB STA 138.8 REPAIRED IAW SRM 55-10-01-2R-11. REPAIR IS CATEGORY "B" REPAIR.