What was found
MAIN CABIN FLOOR STRUCTURE, FORWARD WET AREA (SEC 41) INTERCOSTAL P/N:141A5410-12 LOCATED AT STA 312-STA 328, RBL 31.60, WL 208.1 CRACKED AT FASTENER HOLE LOCATION. GROUNDED - YES. REMOVED INTERCOSTAL IAW SRM 51-40-02-0G-01, LOCATED AND DRILLED NEW INTERCOSTAL IAW SRM 51-40-05-0G-0, INSTALLED NEW INTERCOSTAL IAW DWG 141A5400 REV- SHT 39 AND SRM 51-40-02-0G-0.