What was found
ON MASTER CAUTION RECALL AFTER START AIR COND. ZONE TEMP CONT CAB, ILLUMINATED. FOLLOWED QRH VERIFIED VALVE WORKED W/ PROCEDURE. GROUNDED - YES. RELEASED PER MEL 21-21G FLIGHT DECK PRIMARY TEMP CONT INOP. CLEANED CONT CABIN TEMP SENSOR FILTER. ACCOMP ZONE TEMP CONT BITE. NR 1 SHOWS NO FAULTS. NR 2 SHOWS TRIM VALVE (V143) FLT DECK FAULT. CLEARED FAULT RERAN BITE TEST, TEST PASS NO FAULTS NOW ON NR 2 CONTLR. A/C RELEASED PER MEL 21-21G REMOVED. REF FIM 21-62 TASK 801 & AMM 21-61-06-400-801.